eng Русский язык

Intertherm 891

A one pack oleoresinous/ aluminium coating.

INTENDED USES

As a light reflective finish for cargo holds, pipes, etc. Intertherm 891 is suitable for use on surfaces that are likely to reach dry heat temperatures of up to 250°C. This may be extended up to 315°C if the dry film thickness is reduced to 15μm.
For use at Newbuilding, Maintenance & Repair or On Board Maintenance.

color

HTA002-Aluminium

Finish/Sheen Not applicable
Part B (Curing Agent) Not applicable
Volume Solids 48% ±2% (ISO 3233:1998)
Mix Ratio

1.00 volume(s) Part A to 1 volume(s) Part B

Typical Film Thickness

25 microns dry (52 microns wet)

Theoretical Coverage

19.20 m2/litre at 25 microns dft, allow appropriate loss factors

Method of Application Airless Spray, Brush, Conventional Spray, Roller
Flash Point

Single Pack 43°C

Drying Information

  Substrate Temperature
  5°C 15°C 25°C 35°C
Touch Dry [ISO 9117/3:2010] 18 hrs 12 hrs 8 hrs 6 hrs
Hard Dry [ISO 9117-1:2009] 72 hrs 36 hrs 24 hrs 24 hrs

Overcoating Data

see limitations

Overcoated By Substrate Temperature
  5°C 15°C 25°C 35°C
  Min Max Min Max Min Max Min Max
Intertherm 891 24 hrs ext 24 hrs ext 24 hrs ext 16 hrs ext

REGULATORY DATA

VOC 420 g/lt as supplied (EPA Method 24) 456 g/kg of liquid paint as supplied. EU Solvent Emissions Directive (Council Directive 1999/13/EC)

Note.

VOC values are typical and are provided for guidance purposes only. These may be subject to variation depending on factors such as differences in colour and normal manufacturing tolerances.

CERTIFICATION

When used as part of an approved scheme, this material has the following certification:

  • Food Contact - Carriage of Grain (NOHA)

  • Food Contact - FDA Compliant: Dry Foodstuffs

    Consult your International Paint representative for details.

SYSTEMS AND COMPATIBILITY

Consult your International Paint representative for the system best suited for the surfaces to be protected.

SURFACE PREPARATIONS

Use in accordance with the standard Worldwide Marine Specifications.
All surfaces to be coated should be clean, dry and free from contamination.
High pressure fresh water wash or fresh water wash, as appropriate, and remove all oil or grease, soluble contaminants and other foreign matter in accordance with SSPC-SP1 solvent cleaning.

NEWBUILDING/MAJOR REFURBISHMENT

Intertherm 891 should always be applied over a recommended primer coating scheme. The primer surface should be dry and free from all contamination, and Intertherm 891 must be applied within the overcoating intervals specified (consult the relevant product data sheet).
Areas of breakdown, damage etc. should be prepared to the specified standard (eg. Sa21⁄2 (ISO 8501-1:2007)) and primed prior to the application of Intertherm 891.

REPAIR/OBM

Intertherm 891 should always be applied over a recommended primer coating scheme. The primer surface should be dry and free from all contamination, and Intertherm 891 must be applied within the overcoating intervals specified (consult the relevant product data sheet).
Areas of breakdown, damage etc. should be prepared to the specified standard (eg. Sa21⁄2 (ISO 8501-1:2007)) and primed prior to the application of Intertherm 891.
Intertherm 891 may be applied directly over aged Intertherm 891 following thorough fresh water washing and degreasing provided the coating to be overcoated is in an intact and tightly adherent condition. Loose or flaking coatings should be removed back to a firm edge and Intertherm 891 or an appropriate primer should be used to repair the area before application of the full coat.

Consult your International Paint representative for specific recommendations and procedures.

APPLICATION

Mixing

This material is a one pack coating and should always be mixed thoroughly with a power agitator before application.

Thinner

Not recommended. Use International GTA004 only in exceptional circumstances. DO NOT thin more than allowed by local environmental legislation.

Airless Spray

Recommended
Tip Range 0.33-0.41 mm (13-16 thou)
Total output fluid pressure at spray tip not less than 112 kg/cm2 (1590 p.s.i.)

Conventional Spray

Use suitable proprietary equipment. Thinning may be required.

Brush

Suitable.

Roller

Suitable.

Cleaner

International GTA004

Work Stoppages and Cleanup

Thoroughly flush all equipment with GTA004. All unused material should be stored in tightly closed containers. Partially filled containers may show surface skinning and/or a viscosity increase of the material after storage. Material should be filtered prior to use.

Welding

In the event welding or flame cutting is performed on metal coated with this product, dust and fumes will be emitted which will require the use of appropriate personal protective equipment and adequate local exhaust ventilation. In North America do so in accordance with instruction in ANSI/ASC Z49.1 "Safety in Welding and Cutting."

SAFETY

All work involving the application and use of this product should be performed in compliance with all relevant national Health, Safety & Environmental standards and regulations.

Prior to use, obtain, consult and follow the Material Safety Data Sheet for this product concerning health and safety information. Read and follow all precautionary notices on the Material Safety Data Sheet and container labels. If you do not fully understand these warnings and instructions or if you can not strictly comply with them, do not use this product. Proper ventilation and protective measures must be provided during application and drying to keep solvent vapour concentrations within safe limits and to protect against toxic or oxygen deficient hazards. Take precautions to avoid skin and eye contact (ie. gloves, goggles, face masks, barrier creams etc.) Actual safety measures are dependant on application methods and work environment.

LIMITATIONS

Maximum temperature resistance (315°C) is only achieved at 15μm dry film thickness.
If Intertherm 891 is used over a primer system the heat resistance may be determined by the primer system.
Over application of Intertherm 891 can lead to blistering at high temperatures.
Overcoating information is given for guidance only and is subject to regional variation depending upon local climate and environmental conditions. Consult your local International Paint representative for specific recommendations. The temperature of the surface to be coated must be at least 3°C above the dew point. For optimum application properties bring the material to 21-27°C , unless specifically instructed otherwise, prior to mixing and application. Unmixed material (in closed containers) should be maintained in protected storage in accordance with the information given in the STORAGE section of this data sheet.Technical and application data herein is for the purpose of establishing a general guideline of the coating and proper coating application guidelines. Test performance results were obtained in a controlled laboratory environment and International Paint makes no claim that the exhibited published test results, or any other tests, accurately represent results actually found in all field environments. As application, environmental and design factors can vary significantly, due care should be exercised in the selection, verification of performance and use of the coating.
In the overcoating data section 'ext' = extended overcoating period. Please refer to our Marine Painting Guide - Definitions and Abbreviations available on our website.

UNIT SIZE

Unit Size Vol Pack
20 lt 20 lt 20 lt
5 lt 5 lt 5 lt
5 US gal 5 US gal 5 US gal
1 US gal 1 US gal 1 US gal

UNIT SHIPPING WEIGHT

Unit Size Unit Weight
20 lt 21.24 Kg
5 lt 5.35 Kg
5 US gal 44 lb
1 US gal 8.9 lb

STORAGE

Shelf Life

24 months at 25°C. Subject to reinspection thereafter. Store in dry, shaded conditions away from sources of heat and ignition. Prevent the ingress of moisture as this may lead to a pressure build up in the container.