eng Русский язык

Interline 955

A two pack, glass flake reinforced vinyl ester tank coating.

INTENDED USES

For the protection of galley grey water tanks. For use at Newbuilding or Maintenance & Repair.

color TEA600-White, TEA603-Buff
Finish/Sheen Semi-gloss
Part B (Curing Agent) TEA150, TEA075 if required. (TEA075 is a Retarder, refer to limitations for levels of addition)
Volume Solids 85% (ISO 3233:1998) 100% reactive, although determined volume solids depends upon the application conditions. A recommended working figure is 85%.
Mix Ratio 49 volume(s) Part A to 1 volume(s) Part B
Typical Film Thickness 600 microns dry (706 microns wet)
Theoretical Coverage 1.42 m2/litre at 600 microns dft, allow appropriate loss factors
Method of Application Airless Spray, Brush
Flash Point Part A 32°C; Part B 100°C; Part C 32°C
Induction Period Not applicable

Drying Information

  Substrate Temperature
  10°C 15°C 25°C 35°C
Touch Dry [ISO 1517:73] 5 hrs 4 hrs 4 hrs 4 hrs
Hard Dry [ISO 9117:90] 6 hrs 5 hrs 5 hrs 5 hrs
Walk-on Time 6 hrs 5 hrs 5 hrs 5 hrs
Pot Life

60 mins

60 mins 40 mins 40 mins

Note

When used in non-marine applications, different overcoating intervals apply - refer to the International Protective Coatings Interline 925 datasheet.

Overcoating Data

seelimitations
Overcoated By Substrate Temperature
  10°C 15°C 25°C 35°C
  Min Max Min Max Min Max Min Max
Interline 955 6 hrs 3 days 5 hrs 3 days 5 hrs 2 days 5 hrs 24 hrs

REGULATORY DATA

VOC

35 g/lt as supplied (EPA Method 24)

Note.

VOC values are typical and are provided for guidance purposes only. These may be subject to variation depending on factors such as differences in colour and normal manufacturing tolerances.

SYSTEMS AND COMPATIBILITY

Consult your International Paint representative for the system best suited for the surfaces to be protected. When using in grey water tanks, consult the Interline 955 Grey Water Tank Coating Application Procedures.

SURFACE PREPARATIONS

Use in accordance with the standard Worldwide Marine Specifications. All surfaces to be coated should be clean, dry and free from contamination. High pressure fresh water wash or fresh water wash, as appropriate, and remove all oil or grease, soluble contaminants and other foreign matter in accordance with SSPC-SP1 solvent cleaning.

NEWBUILDING/MAJOR REFURBISHMENT

Where necessary, remove weld spatter and smooth weld seams and sharp edges. Abrasive blast clean to Sa21⁄2 (ISO 8501-1:2007). If oxidation has occurred between blasting and application of Interline 955, the surface should be reblasted to the specified visual standard. Surface defects revealed by the blast cleaning process, should be ground, filled, or treated in the appropriate manner. A surface profile of 75-100 microns is recommended. If a holding primer is required, please consult International Paint for a product suitable for the area of application.

REPAIR

Fresh water wash to remove all dirt and contamination. Degrease according to SSPC-SP1 solvent cleaning. Prepare damaged and corroded areas by blasting to Sa21⁄2 (ISO 8501-1:2007). If oxidation has occurred between blasting and application of Interline 955, the surface should be reblasted to the specified standard.

APPLICATION

Mixing

Material is supplied in 2 containers as a unit. Always mix a complete unit in the proportions supplied.Once the unit has been mixed, it must be used within the working pot life specified. (1) Agitate Base (Part A) with a power agitator. (2) Agitate Curing Agent (Part B).

Thinner

This product must NOT be thinned.

Airless Spray

Recommended. 45:1 pump or greater is necessary. Remove filters from gun and pump. Keep fluid lines as short as possible and use Teflon Packings.

Conventional Spray

Not recommended.

Brush

Application by brush is recommended for small areas only. Multiple coats may be required to achieve specified film thickness.

Roller

Not applicable

Cleaner

International GTA853/GTA407

Work Stoppages and Cleanup

Do not allow material to remain in hoses, gun or spray equipment. Thoroughly flush all equipment with International GTA853/GTA407. Once units of paint have been mixed they should not be resealed and it is advised that after prolonged stoppages work recommences with freshly mixed units. Clean all equipment immediately after use with International GTA853/GTA407. It is good working practice to periodically flush out spray equipment during the course of the working day. Frequency of cleaning will depend upon amount sprayed, temperature, relative humidity and elapsed time, including any delays. Do not exceed pot life limitations. All surplus materials and empty containers should be disposed of in accordance with appropriate regional regulations/legislation.

Welding

In the event welding or flame cutting is performed on metal coated with this product, dust and fumes will be emitted which will require the use of appropriate personal protective equipment and adequate local exhaust ventilation. In North America do so in accordance with instruction in ANSI/ASC Z49.1 "Safety in Welding and Cutting."

SAFETY

All work involving the application and use of this product should be performed in compliance with all relevant national Health, Safety & Environmental standards and regulations. Prior to use, obtain, consult and follow the Material Safety Data Sheet for this product concerning health and safety information. Read and follow all precautionary notices on the Material Safety Data Sheet and container labels. If you do not fully understand these warnings and instructions or if you can not strictly comply with them, do not use this product. Proper ventilation and protective measures must be provided during application and drying to keep solvent vapour concentrations within safe limits and to protect against toxic or oxygen deficient hazards. Take precautions to avoid skin and eye contact (ie. gloves, goggles, face masks, barrier creams etc.) Actual safety measures are dependant on application methods and work environment.

LIMITATIONS

Interline 955 can be applied in a wide range of climatic conditions, including elevated material temperatures up to 35° C. However, at material temperatures greater than 25°C the use of a retarder solution is required in order to maintain the working pot life, allowing normal airless spray methods to be employed. The recommended level of retarder is as follows:- <25°C - No retarder required 25-35°C - 1 unit retarder required These volumes of retarder will maintain the working pot life. The retarder must always be added to the base prior to the addition of the converter/curing agent and mixed thoroughly using a power agitator. This product must NOT be thinned as the use of thinners may severely inhibit the curing mechanism of the coating. This product will not cure adequately below 5°C. Maximum steel temperature at the time of application is 60°C and maximum relative humidity during the application and cure period is 80%. Under direct sunlight exposures or when surface temperatures exceed 35°C Interline 955 should be recoated as soon as the coating will support foot traffic in order to prevent the possibility of intercoat disbondment. Overcoating information is given for guidance only and is subject to regional variation depending upon local climate and environmental conditions. Consult your local International Paint representative for specific recommendations. Apply in good weather. Temperature of the surface to be coated must be at least 3°C above the dew point. For optimum application properties bring the material to 21-27°C, unless specifically instructed otherwise, prior to mixing and application. Unmixed material (in closed containers) should be maintained in protected storage in accordance with information given in the STORAGE Section of this data sheet. Technical and application data herein is for the purpose of establishing a general guideline of the coating application procedures. Test performance results were obtained in a controlled laboratory environment and International Paint makes no claim that the exhibited published test results, or any other tests, accurately represent results found in all field environments. As application, environmental and design factors can vary significantly, due care should be exercised in the selection, verification of performance and use of the coating.

UNIT SIZE

Unit Size Part A Part B
  Vol Pack Vol Pack
20 lt 15 lt 20 lt 5 lt 5 lt
4 US gal 3 US gal 5 US gal 1 US gal 1 US gal

UNIT SHIPPING WEIGHT

Unit Size Unit Weight
20 lt 29.33 KgKg
4 US gal 53.3 lb

STORAGE

Shelf Life 12 months minimum at 25°C. Subject to re-inspection thereafter. Store in dry, shaded conditions away from sources of heat and ignition.