TBT free, controlled depletion polymer (CDP) self polishing antifouling system.
INTENDED USES
For use at Newbuilding or Maintenance & Repair. In repair situations Interspeed 6400 can be applied directly over existing antifoulings.
color | BQA644-Red, BQA648-Brown, BQA642-Blue, BQA643-Green, BQA649- Black |
Finish/Sheen | Not applicable |
Part B (Curing Agent) | Not applicable |
Volume Solids | 60% ±2% (ISO 3233:1998) |
Mix Ratio | Not applicable |
Typical Film Thickness | Range: 75 - 150 microns dry (125 - 250 microns wet) may be specified depending upon end use. |
Theoretical Coverage | Range: 8.0 - 4.0 m²/litre at 75 - 150 microns dft, allow appropriate loss factors |
Method of Application | Airless Spray, Brush, Roller |
Flash Point | Single Pack 27°C |
Drying Information
Substrate Temperature | ||||
-5°C | 5°C | 25°C | 35°C | |
Touch Dry [ISO 9117/3:2010] | 4 hrs | 3.5 hrs | 2 hrs | 60 mins |
Before Flooding | 24 hrs | 20 hrs | 12 hrs | 12 hrs |
note
Overcoating data refers to BQA648 followed by BQA644.
Overcoating Data
see limitations
Overcoated By | Substrate Temperature | |||||||
-5°C |
5°C | 25°C | 35°C | |||||
Min | Max | Min | Max | Min | Max | Min | Max | |
Interspeed 340 | 12 hrs | 6 mths | 10 hrs | 6 mths | 6 hrs | 6 mths | 4 hrs | 3 mths |
REGULATORY DATA
VOC 363 g/lt as supplied (EPA Method 24) 210 g/kg of liquid paint as supplied. EU Solvent Emissions Directive (Council Directive 1999/13/EC)
Note.
VOC values are typical and are provided for guidance purposes only. These may be subject to variation depending on factors such as differences in colour and normal manufacturing tolerances.
SYSTEMS AND COMPATIBILITY
Consult your International Paint representative for the system best suited for the surfaces to be protected.
SURFACE PREPARATIONS
Use in accordance with the standard Worldwide Marine Specifications. All surfaces to be coated should be clean, dry and free from contamination. High pressure fresh water wash or fresh water wash, as appropriate, and remove all oil or grease, soluble contaminants and other foreign matter in accordance with SSPC-SP1 solvent cleaning.
NEWBUILDING
Dependent on yard procedures. Consult International Paint.
MAJOR REFURBISHMENT
Interspeed 6400 should always be applied over a recommended primer coating scheme. The primer surface should be dry and free from all contamination. Interspeed 6400 must be applied within the overcoating intervals specified for the primer (consult the relevant primer data sheet). Areas of breakdown, damage etc., should be prepared to the specified standard e.g. Sa2½ (ISO 8501-1:2007)) and primed prior to the application of Interspeed 6400.
REPAIR
CDP (Controlled Depletion Polymer) antifoulings can build up a thick leached layer during service which must be removed prior to application of Interspeed 6400. To remove this leached layer, treat the entire area by close high pressure fresh water washing using a fan-jet lance held close to the surface (3,000 p.s.i., 211 kg/cm²) as soon as the vessel enters dock and before it dries out. Consult International Paint for alternative methods of surface preparation. Repair corroded areas with the recommended primer coating scheme and apply Interspeed 6400 within the overcoating interval specified for the primer (consult the relevant primer data sheet). Ensure that the total area is clean and dry, then overcoat with Interspeed 6400.
Consult your International Paint representative for specific recommendations.
APPLICATION
Mixing
This material is a one pack coating and should always be mixed thoroughly with a power agitator before application.Thinner
Not recommended. Use International GTA007 only in exceptional circumstances. DO NOT thin more than allowed by local environmental legislation.
Airless Spray
Recommended
Tip Range 0.66-0.79 mm (26-31 thou)
Total output fluid pressure at spray tip not less than 176 kg/cm² (2500 p.s.i.)
Conventional Spray
Application by conventional spray is not recommended.Brush
Application by brush is recommended for small areas only. Multiple coats may be required to achieve specified film thickness.
Roller
Application by roller is recommended for small areas only. Multiple coats may be required to achieve specified film thickness.
Cleaner
International GTA007
Work Stoppages and Cleanup
Thoroughly flush all equipment with GTA007. All unused material should be stored in tightly closed containers. Partially filled containers may show surface skinning and/or a viscosity increase of the material after storage. Material should be filtered prior to use.
Welding
In the event welding or flame cutting is performed on metal coated with this product, dust and fumes will be emitted which will require the use of appropriate personal protective equipment and adequate local exhaust ventilation. In North America do so in accordance with instruction in ANSI/ASC Z49.1 "Safety in Welding and Cutting."
SAFETY
All work involving the application and use of this product should be performed in compliance with all relevant national Health, Safety & Environmental standards and regulations.
Prior to use, obtain, consult and follow the Material Safety Data Sheet for this product concerning health and safety information. Read and follow all precautionary notices on the Material Safety Data Sheet and container labels. If you do not fully understand these warnings and instructions or if you can not strictly comply with them, do not use this product. Proper ventilation and protective measures must be provided during application and drying to keep solvent vapour concentrations within safe limits and to protect against toxic or oxygen deficient hazards. Take precautions to avoid skin and eye contact (ie. gloves, goggles, face masks, barrier creams etc.) Actual safety measures are dependant on application methods and work environment. EMERGENCY CONTACT
LIMITATIONS
If the following maximum recommended exposure times before flooding are exceeded, antifouling performance may be impaired: Temperate conditions - 6 months, Tropical conditions - 3 months On immersion Interspeed 6400 changes colour.
Overcoating information is given for guidance only and is subject to regional variation depending upon local climate and environmental conditions. Consult your local International Paint representative for specific recommendations. Apply in good weather. Temperature of the surface to be coated must be at least 3°C above the dew point. For optimum application properties bring the material to 21-27°C, unless specifically instructed otherwise, prior to mixing and application. Unmixed material (in closed containers) should be maintained in protected storage in accordance with information given in the STORAGE Section of this data sheet. Technical and application data herein is for the purpose of establishing a general guideline of the coating application procedures. Test performance results were obtained in a controlled laboratory environment and International Paint makes no claim that the exhibited published test results, or any other tests, accurately represent results found in all field environments. As application, environmental and design factors can vary significantly, due care should be exercised in the selection, verification of performance and use of the coating.
UNIT SIZE
Unit Size | ||
Vol | Pack | |
20 lt | 20 lt | 20 lt |
For availability of other unit sizes consult International Paint
UNIT SHIPPING WEIGHT
Unit Size | Unit Weight |
20 lt | 39.7 Kg |
STORAGE
Shelf Life | 6 months minimum at 25°C. Subject to re-inspection thereafter. Store in dry, shaded conditions away from sources of heat and ignition. |