eng Русский язык

Interprime 198

A quick drying, one pack primer. Interprime 198 is surface tolerant, compatible with most substrates and can be overcoated with a wide range of finishes.

Intended uses

For the maintenance of above water areas. Approved for the carriage of grain when used as part of an approved scheme. For use at Maintenance & Repair or On Board Maintenance.

color CPA097-White, CPA098-Grey, CPA099-Red
Finish/Sheen Matt
Part B (Curing Agent) Not applicable
Volume Solids 41% ±2% (ISO 3233:1998)
Mix Ratio Not applicable
Typical Film Thickness 75 microns dry (183 microns wet)
Theoretical Coverage 5.47 m2/litre at 75 microns dft, allow appropriate loss factors
Method of Application Airless Spray, Brush, Roller
Flash Point Single Pack 35°C

Drying Information

  Substrate Temperature
  -5°C 5°C 25°C 35°C
Touch Dry [ISO 1517:73] 8 hrs 3 hrs 60 mins 30 mins
Hard Dry [ISO 9117:90] 48 hrs 24 hrs 4 hrs 2 hrs

Overcoating Data

Overcoated By Substrate Temperature
  5°C 10°C 25°C 35°C
  Min Max Min Max Min Max Min Max
Interfine 599 - - 9 hrs 3 days 3 hrs 2 days 60 mins 24 hrs
Interlac 665 24 hrs 3 days 6 hrs 3 days 3 hrs 2 days 60 mins 24 hrs
Interprime 198 8 hrs ext 3 hrs ext 60 mins ext 30 mins ext
Intersheen 579 24 hrs 3 days 24 hrs 3 days 12 hrs 2 days 6 hrs 24 hrs
Interthane 990 - - 24 hrs 7 days 12 hrs 7 days 6 hrs 3 days
Intertherm 891 24 hrs 28 days 6 hrs 28 days 2 hrs 28 days 60 mins 28 days

Regulatory data

VOC

506 g/lt as supplied (EPA Method 24) 416 g/kg of liquid paint as supplied. EU Solvent Emissions Directive (Council Directive 1999/13/EC)

Note.

VOC values are typical and are provided for guidance purposes only. These may be subject to variation depending on factors such as differences in colour and normal manufacturing tolerances.

Certification

When used as part of an approved scheme, this material has the following certification:

  • Fire Resistance - Surface Spread of Flame (WFR) - (IMO Resolution A653 (16))
  • Fire Resistance - Surface Spread of Flame (Korean Register of Shipping)
  • Fire Resistance - MSC61(67) Smoke & Toxicity (WFR)
  • Food Contact - Carriage of Grain (NOHA)
  • Fire Resistance - Marine Equipment Directive compliant

Consult your International Paint representative for details.

System and compatibility

Consult your International Paint representative for the system best suited for the surfaces to be protected.

Surface preparations

Use in accordance with the standard Worldwide Marine Specifications. All surfaces to be coated should be clean, dry and free from contamination. High pressure fresh water wash or fresh water wash, as appropriate, and remove all oil or grease, soluble contaminants and other foreign matter in accordance with SSPC-SP1 solvent cleaning.

REPAIR/OBM

Prepare area to be repaired to a minimum of St2 (ISO 8501-1:1998). Higher levels of surface preparation by abrasive blasting to Sa2 (ISO 8501-1:2001) or hydroblasting to HB2M (International Paint Hydroblasting Standards), will enhance product performance. Feather or chip back surrounding area to a sound edge. Ensure that the area is clean and dry prior to application of Interprime 198. Overlap the primer onto existing coatings by approximately 2-3cm. Consult your International Paint representative for specific recommendations.

APPLICATION

Mixing

This material is a one pack coating and should always be mixed thoroughly with a power agitator before application.

Thinner

Not recommended. Use International GTA007 only in exceptional circumstances. DO NOT thin more than allowed by local environmental legislation.

Airless Spray

Recommended Tip Range 0.53-0.66 mm (21-26 thou) Total output fluid pressure at spray tip not less than 176 kg/cm2 (2500 p.s.i.)

Conventional Spray

Application by conventional spray is not recommended.

Brush

Recommended. Multiple coats may be required to achieve specified dft.

Roller

Recommended. Multiple coats may be required to achieve specified dft.

Cleaner

International GTA007

Work Stoppages and Cleanup

Thoroughly flush all equipment with International GTA007. All unused material should be stored in tightly closed containers. Partially filled containers may show surface skinning and/or a viscosity increase of the material after storage. Material should be filtered prior to use.

Welding

In the event welding or flame cutting is performed on metal coated with this product, dust and fumes will be emitted which will require the use of appropriate personal protective equipment and adequate local exhaust ventilation. In North America do so in accordance with instruction in ANSI/ASC Z49.1 "Safety in Welding and Cutting."

SAFETY

All work involving the application and use of this product should be performed in compliance with all relevant national Health, Safety & Environmental standards and regulations. Prior to use, obtain, consult and follow the Material Safety Data Sheet for this product concerning health and safety information. Read and follow all precautionary notices on the Material Safety Data Sheet and container labels. If you do not fully understand these warnings and instructions or if you can not strictly comply with them, do not use this product. Proper ventilation and protective measures must be provided during application and drying to keep solvent vapour concentrations within safe limits and to protect against toxic or oxygen deficient hazards. Take precautions to avoid skin and eye contact (ie. gloves, goggles, face masks, barrier creams etc.) Actual safety measures are dependant on application methods and work environment.

Limitations

It is recommended that Interprime 198 is not overcoated with epoxy coatings. In certain regions, for specific customer requests and where cosmetic properties are not of concern, Interprime 198 may be applied without a cosmetic finish. Consult your regional technical centre for guidelines and details of colours available.

Overcoating information is given for guidance only and is subject to regional variation depending upon local climate and environmental conditions. Consult your local International Paint representative for specific recommendations. Apply in good weather. Temperature of the surface to be coated must be at least 3°C above the dew point. For optimum application properties bring the material to 21-27°C, unless specifically instructed otherwise, prior to mixing and application. Unmixed material (in closed containers) should be maintained in protected storage in accordance with information given in the STORAGE Section of this data sheet. Technical and application data herein is for the purpose of establishing a general guideline of the coating application procedures. Test performance results were obtained in a controlled laboratory environment and International Paint makes no claim that the exhibited published test results, or any other tests, accurately represent results found in all field environments. As application, environmental and design factors can vary significantly, due care should be exercised in the selection, verification of performance and use of the coating.

Unit size

Unit size  
  Vol Pack
5 lt 5 lt 5 lt
20 lt 17.83 lt 20 lt
1 US gal 1 US gal 1 US gal
5 US gal 5 US gal 5 US gal

For availability of other unit sizes consult International Paint

Unit shipping weight

Unit size Unit Weight
20 lt 26.7 Kg
5 lt 6.71 Kg
5 US gal 60.9 lb
1 US gal 12.2 lb

Storage

Shelf Life 24 months minimum at 25°C. Subject to reinspection thereafter. Store in dry, shaded conditions away from sources of heat and ignition
Яндекс.Метрика