A two pack, low VOC polyurethane finish. Outstanding resistance to severe weathering. High gloss. Good abrasion, chemical and solvent resistance.
INTENDED USES
A cosmetic finish for above water areas. For use at Newbuilding, Maintenance & Repair or On Board Maintenance.
color | 99002-Black, 99010-White and a range of colours |
Finish/Sheen | High Gloss |
Part B (Curing Agent) | 990B |
Volume Solids | 68% ±3% (ASTM D2697-86) |
Mix Ratio | 9 volume(s) Part A to 1 volume(s) Part B |
Typical Film Thickness | 5.00 volumes Part A to 1 volume Part B |
Theoretical Coverage | 13.60 m2/litre at 50 microns dft, allow appropriate loss factors |
Method of Application | Airless Spray, Brush, Conventional Spray, Roller |
Flash Point | Part A 38°C; Part B 57°C; Mixed 39°C (Setaflash) (ASTM D-3278) |
Induction Period | None required |
Drying Information
Substrate Temperature | ||||
5°C | 10°C | 25°C | 35°C | |
Touch Dry [ASTM D1640 7.5.1] | 3.5 hrs | 3 hrs | 2 hrs | 75 mins |
Hard Dry [ASTM D1640 7.7] | 24 hrs | 17 hrs | 6 hrs | 3 hrs |
Pot Life | 7 hrs | 5.5 hrs | 3 hrs | 2 hrs |
Overcoating Data
seelimitationsOvercoated By | Substrate Temperature | |||||||
5°C | 10°C | 25°C | 35°C | |||||
Min | Max | Min | Max | Min | Max | Min | Max | |
Interthane 990HS | 24 hrs | ext | 17 hrs | ext | 6 hrs | ext | 3 hrs | ext |
Note
Recoat limits are defined as 990HS, at specified temperatures within a relative humidity range of 40-60%. For surface temperatures in excess of 32°C, see "Limitations" section. 
REGULATORY DATA
VOC
327 g/lt as supplied (EPA Method 24)
MIL SPEC
MIL-PRF-24667B, Type I, II, III & VIII Composition G MIL-PRF-24667B, Type I & VII, Composition L For colour marking purposes only
SYSTEMS AND COMPATIBILITY
Consult your International Paint representative for the system best suited for the surfaces to be protected.
SURFACE PREPARATIONS
Paint only clean, dry surfaces. Remove all grease, oil, soluble contaminants and other foreign matter by "solvent cleaning" (SSPC-SP1).
Unpainted surfaces:
Prepare surface and apply recommended primer. Apply one or more coats of Interthane 990HS as specified. (Consult the relevant primer data sheet for surface preparation and overcoating information.)
Previously Painted Surfaces
Remove all mill scale, loose rust, loose paint and other foreign matter by "Hand or Power Tool Cleaning" (SSPC-SP2 or SP3, respectively). Sand or 'Brush Blast' (SSPC-SP7) any hard glossy areas until dull. Spot prime bare areas as recommended and apply one or more coats of Interthane 990HS as specified. Consult the relevant primer data sheet for specific surface preparation and overcoating information. Check integrity of existing coating system and apply a representative test patch to confirm compatibility. Consult your International Paint representative for procedures.
APPLICATION
Apply by brush, roller or spray. Apply at 73 microns wet which will give 50 microns dry film thickness, as specified. Consult the following equipment recommendations or utilize suitable equal.
Mixing
Material is supplied in 2 containers as a unit. Always mix a complete unit in the proportions supplied. (1) Agitate Part A with a power agitator, (2) Combine entire contents of Part A and B and mix thoroughly with a power agitator.
Thinner
Range of colours available from Chromascan. Most colours require that containers be slightly short filled to accommodate the addition of colourant. Actual coverage will depend upon amount of colourant added and should be taken into consideration when ordering. A limited number of Interthane 990HS tinted colours may require more than one coat for complete hiding.
Airless Spray
Minimum 30:1 ratio pump; 0.013"-0.019" (331-483 microns) orifice tip; 3/8" (9.5mm) ID high pressure material hose; 60 mesh tip filter.
Conventional Spray
DeVilbiss MBC-510 gun E tip and 704 air cap; 3/8" (9.5 mm) ID material hose; double regulated pressure tank with oil and moisture separator.
Brush
Use appropriate size China bristle brush.
Roller
Use All Purpose Roller cover with 3/8" (9.5 mm) smooth to medium nap. Prewash roller cover to remove loose fibres prior to use.
Work Stoppages and Cleanup
Clean all equipment immediately after use with International GTA056. Spray equipment requires flushing with this solvent. It is good working practice to periodically flush out spray equipment during the course of the working day. Frequency will depend upon factors such as amount sprayed, temperature and elapsed time including work stoppages. Monitor material condition. Do not exceed pot life limitations. All surplus materials and empty containers should be disposed of in accordance with appropriate regional regulations/legislation.
Welding
In the event welding or flame cutting is performed on metal coated with this product, dust and fumes will be emitted which will require the use of appropriate personal protective equipment and adequate local exhaust ventilation. In North America do so in accordance with instruction in ANSI/ASC Z49.1 "Safety in Welding and Cutting."
SAFETY
All work involving the application and use of this product should be performed in compliance with all relevant national Health, Safety & Environmental standards and regulations. Prior to use, obtain, consult and follow the Material Safety Data Sheet for this product concerning health and safety information. Read and follow all precautionary notices on the Material Safety Data Sheet and container labels. If you do not fully understand these warnings and instructions or if you can not strictly comply with them, do not use this product. Proper ventilation and protective measures must be provided during application and drying to keep solvent vapour concentrations within safe limits and to protect against toxic or oxygen deficient hazards. Take precautions to avoid skin and eye contact (ie. gloves, goggles, face masks, barrier creams etc.) Actual safety measures are dependant on application methods and work environment.
LIMITATIONS
Apply in good weather when air and surface temperatures are above 2°C. Surface temperature must be at least 3°C above dew point. For optimum application properties, bring material to 21-27°C prior to mixing and application. Unmixed material (in closed containers) should be maintained in protected storage between 4-38°C. Film thickness above 100 microns and below microns DFT may adversely effect appearance and performance. If surface temperatures exceed 32°C, then after 72 hours clean with GMA571 biodegradable cleaner prior to overcoating. For recoat beyond 30 days at any surface temperature additional surface preparation may be required. Dry Temperature Resistance 93°C. Overcoating information is given for guidance only and is subject to regional variation depending upon local climate and environmental conditions. Consult your local International Paint representative for specific recommendations. Technical and application data herein is for the purpose of establishing a general guideline of the coating and proper coating application guidelines. Test performance results were obtained in a controlled laboratory environment and International Paint makes no claim that the exhibited published test results, or any other tests, accurately represent results actually found in all field environments. As application, environmental and design factors can vary significantly, due care should be exercised in the selection, verification of performance and use of the coating.
UNIT SIZE
Unit Size | Part A | Part B | ||
Vol | Pack | Vol | Pack | |
1 US gal | 1 US gal | 1 US gal | 1 US gal | 1 US gal |
5 US gal | 5 US gal | 5 US gal | 0.5 US gal | 0.5 US gal |
UNIT SHIPPING WEIGHT
Unit Size | Unit Weight |
1 US gal | 12.25lb |
5 US gal | 60.7 lb |
STORAGE
Shelf Life | 24 months from date of manufacture when maintained in protected storage at 4-38°C. Subject to reinspection thereafter. Store in dry, shaded conditions away from sources of heat and ignition. |